Summary

Suspended, January 2031. Observational study, 50 participants (estimated). Lead sponsor Edwards Lifesciences; United States. Primary measures: Subject's Occurrence Rate of the Composite Safety Endpoint; Subject's Occurrence Rate of Valve Malpositioning and 1 more.

Registry record

As filed in ClinicalTrials.gov.

Title
INSPIRIS RESILIA Aortic Valve, Valve-in-Valve Surveillance Study
Official title
Not reported
Lead sponsor
Edwards Lifesciences
Phase
Observational
Overall status
Suspended
Start date
June 30, 2028
Completion date
January 31, 2031
Enrollment
50 (estimated)
Sites
7

Conditions

As the registry lists them.

aortic valve replacement

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
18 Years
Healthy volunteers
No
Study type
Observational
Sites
7
Countries
United States
Lead sponsor
Edwards Lifesciences

Primary endpoints

Registered primary outcome measures; 3 primary.

Registered primary endpoints
Measure Time frame
Subject's Occurrence Rate of the Composite Safety Endpoint Events occurring within 30 days of valve-in-valve procedure
Show registry wording

The primary safety endpoint is a composite endpoint defined as all-cause mortality, all stroke (disabling and non-disabling), life-threatening bleeding, new requirement for dialysis, coronary artery compression or obstruction, major vascular complication, and valve-related dysfunction requiring reintervention.

Data will be reported as the number (and percent) of subjects who experience an event divided by the number of enrolled subjects times 100.

Subject's Occurrence Rate of Valve Malpositioning Events occurring within 30 days of valve-in-valve procedure
Show registry wording

Valve malpositioning includes all instances of ViV-TAVR migration, embolization, and valve recapture or retrieval.

Data will be reported as the number (and percent) of subjects who experience an event divided by the number of enrolled subjects times 100.

Subject's INSPIRIS RESILIA Valve Expansion Post Valve in Valve Procedure Compared to Baseline Day 30, compared to baseline
Show registry wording

A primary effectiveness endpoint is the expansion, measured in mm\^2, of INSPIRIS valve for sizes 19mm-25mm, following the Edwards transcatheter aortic valve implantation.