Clinical trial
Hand Perfusion and Pulse Oximetry Performance
NCT06925646 is registered in ClinicalTrials.gov with Mayo Clinic as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started September 2027. Observational study, 20 participants (estimated). Lead sponsor Mayo Clinic; United States. Primary measures: Arterial oxygen saturation measured via arterial blood gas sample (Sa02); Arterial oxygen saturation measured via pulse oximeters (Sp02).
Registry record
As filed in ClinicalTrials.gov.
- Title
- Hand Perfusion and Pulse Oximetry Performance
- Official title
- Not reported
- Lead sponsor
- Mayo Clinic
- Phase
- Observational
- Overall status
- Not yet recruiting
- Start date
- September 1, 2027
- Completion date
- October 1, 2028
- Enrollment
- 20 (estimated)
- Sites
- 1
Conditions
As the registry lists them.
oxygen saturation
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 18 Years
- Maximum age
- 65 Years
- Healthy volunteers
- Yes
- Study type
- Observational
- Sites
- 1
- Countries
- United States
- Lead sponsor
- Mayo Clinic
Arms
As registered; 1 arm.
| Arm | Type | Interventions |
|---|---|---|
| Study group | Baseline hypoxic test, Finger hyperperfusion via adenosine, Finger hypoperfusion via by norepinephrine | |
Show registry wordingThe study group will consist of 20 healthy non-smokers, with BMIs between 18-30 kg·m-2, free of cardiopulmonary diseases. Subjects will wear multiple pulse oximeter devices to measure arterial oxygen saturation (SpO2). Two fingers of each hand will be be equipped with identical FDA approved devices from two different commercial manufacturers. The third finger of each hand be equipped with a Mayo device developed by the SPPDG program for use by the US Military. Two wrist worn PPG-equipped "watches" (Garmin Fenix and the Mayo Clinic Developed SPPDG Watch) will be worn on each arm. One will be placed in the normal watch position (dorsal forearm) where pigmentation will generally be the darkest; the other will be placed on the volar forearm where pigmentation is generally less. Subjects will also have an indwelling catheter placed in the brachial artery to collect samples for blood gases. | ||
Primary endpoints
Registered primary outcome measures; 2 primary.
| Measure | Time frame |
|---|---|
| Arterial oxygen saturation measured via arterial blood gas sample (Sa02) | 30 minutes, 90 minutes, 3 hours |
Show registry wordingArterial oxygen saturation will be obtained via a blood sample at the end of each stage of the breath down protocols and is reported as a percentage. | |
| Arterial oxygen saturation measured via pulse oximeters (Sp02) | 30 minutes, 90 minutes, 3 hours |
Show registry wordingArterial oxygen saturation will be obtained via pulse oximeter reading at the end of each stage of the breath down protocols and is reported as a percentage. | |
Lead sponsor's other trials
Mayo Clinic, most recent start first.
+3,268 more trials See the organization page