Clinical trial
Monitoring of Patient Physiological Parameters in Real Life Using OXYFLEX® Biosensors Versus Standard Monitoring
NCT07037784 is registered in ClinicalTrials.gov with Centre Hospitalier Intercommunal de Toulon La Seyne sur Mer as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started July 2026. Interventional study, 102 participants (estimated). Lead sponsor Centre Hospitalier Intercommunal de Toulon La Seyne sur Mer; France. Primary measures: heart rate measurement; respiratory rate measurement and 3 more.
Registry record
As filed in ClinicalTrials.gov.
- Title
- Monitoring of Patient Physiological Parameters in Real Life Using OXYFLEX® Biosensors Versus Standard Monitoring
- Official title
- Monitoring of Physiological Parameters in Real Life in Patients Managed in Anesthesia, Rehabilitation/Intensive Care Unit and Traumatology Services, Using OXYFLEX® Biosensors Versus Standard Monitoring
- Lead sponsor
- Centre Hospitalier Intercommunal de Toulon La Seyne sur Mer
- Phase
- Not applicable
- Overall status
- Not yet recruiting
- Start date
- July 31, 2026
- Completion date
- January 31, 2027
- Enrollment
- 102 (estimated)
- Sites
- 1
Conditions
As the registry lists them.
physiological parameters
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 18 Years
- Healthy volunteers
- No
- Study type
- Interventional
- Sites
- 1
- Countries
- France
- Lead sponsor
- Centre Hospitalier Intercommunal de Toulon La Seyne sur Mer
Arms
As registered; 1 arm.
| Arm | Type | Interventions |
|---|---|---|
| Patients managed in anesthesia, rehabilitation/instensive care unit and traumatology services. | Experimental | Continuous monitoring of vital constants with OXYFLEX® biosensor. |
Show registry wordingDemonstrate the relevance of the data collected from patients treated in different hospital departments, including critical emergencies, intensive care, general intensive care units, and the operating room. | ||
Primary endpoints
Registered primary outcome measures; 5 primary.
| Measure | Time frame |
|---|---|
| heart rate measurement | for a maximum of 10 hours |
Show registry wordingThe data collected by the OXYFLEX biosensor will be compared to data from standard monitoring using concordance tests, such as the Bland-Altman test, the Intraclass Correlation Coefficient (ICC), and the mean of absolute errors. These analyses will allow for the evaluation of the accuracy and reproducibility of the measurements taken with the OXYFLEX biosensor. | |
| respiratory rate measurement | for a maximum of 10 hours |
Show registry wordingThe data collected by the OXYFLEX® biosensor will be compared to data from standard monitoring using concordance tests, such as the Bland-Altman test, the Intraclass Correlation Coefficient (ICC), and the mean of absolute errors. These analyses will allow for the evaluation of the accuracy and reproducibility of the measurements taken with the OXYFLEX® biosensor. | |
| temperature measurement | for a maximum of 10 hours |
Show registry wordingThe data collected by the OXYFLEX® biosensor will be compared to data from standard monitoring using concordance tests, such as the Bland-Altman test, the Intraclass Correlation Coefficient (ICC), and the mean of absolute errors. These analyses will allow for the evaluation of the accuracy and reproducibility of the measurements taken with the OXYFLEX® biosensor. | |
| pulse oxygen saturation measurement | for a maximum of 10 hours |
Show registry wordingThe data collected by the OXYFLEX® biosensor will be compared to data from standard monitoring using concordance tests, such as the Bland-Altman test, the Intraclass Correlation Coefficient (ICC), and the mean of absolute errors. These analyses will allow for the evaluation of the accuracy and reproducibility of the measurements taken with the OXYFLEX® biosensor. | |
| hemoglobin measurement | for a maximum of 10 hours |
Show registry wordingThe data collected by the OXYFLEX® biosensor will be compared to data from standard monitoring using concordance tests, such as the Bland-Altman test, the Intraclass Correlation Coefficient (ICC), and the mean of absolute errors. These analyses will allow for the evaluation of the accuracy and reproducibility of the measurements taken with the OXYFLEX® biosensor. | |
Lead sponsor's other trials
Centre Hospitalier Intercommunal de Toulon La Seyne sur Mer, most recent start first.
+72 more trials