Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

Acute Effects of Upper Arm Tissue Flossing on Upper Extremity Performance and Power

NCT07670793 is registered in ClinicalTrials.gov with Erzurum Technical University as lead sponsor.

NCT NCT07670793 Completed Not applicable 28 participants (actual) Started 2026 1 site

Follow this trial by email Email me the PDF

Get the NCT07670793 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Completed, October 2026. Interventional study, 28 participants (actual). Lead sponsor Erzurum Technical University; Turkey (Türkiye). Primary measures: Seated Medicine Ball Throw (SMBT) distance; Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) score.

Registry record

As filed in ClinicalTrials.gov.

Title
Acute Effects of Upper Arm Tissue Flossing on Upper Extremity Performance and Power
Official title
Acute Effects of Upper Arm Tissue Flossing on Closed-Chain Upper Extremity Stability and Explosive Upper-Body Power: A Randomized Sham-Controlled Trial
Lead sponsor
Erzurum Technical University
Phase
Not applicable
Overall status
Completed
Start date
July 1, 2026
Completion date
October 3, 2026
Enrollment
28 (actual)
Sites
1

Conditions

As the registry lists them.

healthy volunteers, tissue flossing, upper extremity performance

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
18 Years
Maximum age
35 Years
Healthy volunteers
Yes
Study type
Interventional
Sites
1
Countries
Turkey (Türkiye)
Lead sponsor
Erzurum Technical University

Arms

As registered; 2 arms.

Registered arms
Arm Type Interventions
Active Flossing Group Experimental Active Myofascial Compression, Sham Myofascial Wrap
Show registry wording

Participants (n=14) receive a structured circumferential compression protocol on their dominant upper arm using an elastic latex floss band stretched to moderate tension, followed by a brief active movement sequence.

Sham Flossing Sham comparator Active Myofascial Compression, Sham Myofascial Wrap
Show registry wording

Participants (n=14) receive a loose, minimal-tension wrap on their dominant upper arm using the same floss band type, performing the identical active movement sequence to isolate the effects of compression intensity

Primary endpoints

Registered primary outcome measures; 2 primary.

Registered primary endpoints
Measure Time frame
Seated Medicine Ball Throw (SMBT) distance Measured at three time points: Baseline (Pre-intervention), 2 minutes post-removal, and 15 minutes post-removal
Show registry wording

Upper-extremity explosive power was assessed using the seated medicine ball throw. Participants were seated upright with back support and projected a 2-kg medicine ball horizontally as far as possible in a chest-pass motion. Throw distance was measured from a fixed start line to the point of initial ball contact.

Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) score Measured at three time points: Baseline (Pre-intervention), 2 minutes post-removal, and 15 minutes post-removal.
Show registry wording

Upper-extremity closed-chain stability was assessed using the CKCUEST. Participants assumed a full push-up (high-plank) position with hands placed on two parallel strips of tape positioned 91.4 cm apart. Participants alternately touched the opposite hand as rapidly as possible for 15 seconds. The metric recorded is the total number of completed hand touches within the 15-second interval.

Lead sponsor's other trials

Erzurum Technical University, most recent start first.