Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

Comparison of Short-Axis and Long-Axis Internal Jugular Vein Cannulation for First-Pass Success

NCT07691554 is registered in ClinicalTrials.gov with University of Health Sciences Lahore as lead sponsor.

NCT NCT07691554 Not yet recruiting Not applicable 10 participants (estimated) Started 2026 1 site

Follow this trial by email Email me the PDF

Get the NCT07691554 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Not yet recruiting, started October 2026. Interventional study, 10 participants (estimated). Lead sponsor University of Health Sciences Lahore; Pakistan. Primary measure: First-Pass Success Rate of Ultrasound-Guided Internal Jugular Vein Cannulation. 3 linked papers (newest 2022).

Registry record

As filed in ClinicalTrials.gov.

Title
Comparison of Short-Axis and Long-Axis Internal Jugular Vein Cannulation for First-Pass Success
Official title
Comparison Between Short Axis and Long Axis For Cannulation Of Internal Jugular Vein in Terms Of First Pass Success
Lead sponsor
University of Health Sciences Lahore
Phase
Not applicable
Overall status
Not yet recruiting
Start date
October 31, 2026
Completion date
April 30, 2027
Enrollment
10 (estimated)
Sites
1

Conditions

As the registry lists them.

cannulation of internal jugular vein

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
25 Years
Maximum age
70 Years
Healthy volunteers
No
Study type
Interventional
Sites
1
Countries
Pakistan
Lead sponsor
University of Health Sciences Lahore

Arms

As registered; 2 arms.

Registered arms
Arm Type Interventions
Group A (Short-Axis Approach) Active comparator Short-Axis Ultrasound-Guided Internal Jugular Vein Cannulation
Show registry wording

In this approach, IJV will be visualized by placing the transducer in a transverse orientation on the patient neck at the level of the cricoid cartilage. The needle will be inserted at 60° to the vertical and will be advanced toward the vein employing gentle aspiration on the attached syringe. Entry to the vein will be confirmed by visualizing indentation of the anterior wall of the vein followed by blood in the syringe and by visualizing the tip of the needle inside the vein. Guide wire will be passed followed by dilator insertion and finally central vein line.

Group B (Long-Axis Approach) Active comparator Long-Axis Ultrasound-Guided Internal Jugular Vein Cannulation
Show registry wording

In this approach, the probe will be centered on the IJV and rotated through 90° in a clockwise direction resulting in long axis image of the vein. The needle insertion point will be directly beneath the most proximal end of the ultrasound probe. The needle will be inserted at 30° to the vertical and will be advanced toward the vein employing gentle aspiration. Entry to the vein will be confirmed by visualizing needle entry into the vein followed by aspiration of blood in the syringe. Guide wire will be inserted followed by dilator insertion and finally central vein line.

Primary endpoints

Registered primary outcome measures; 1 primary.

Registered primary endpoints
Measure Time frame
First-Pass Success Rate of Ultrasound-Guided Internal Jugular Vein Cannulation Assessed during the cannulation procedure (within 5 minutes of initiation of cannulation).
Show registry wording

First-pass success rate of ultrasound-guided internal jugular vein cannulation, defined as successful venous cannulation with a single skin puncture and needle pass.