Clinical trial
Comparison of Short-Axis and Long-Axis Internal Jugular Vein Cannulation for First-Pass Success
NCT07691554 is registered in ClinicalTrials.gov with University of Health Sciences Lahore as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started October 2026. Interventional study, 10 participants (estimated). Lead sponsor University of Health Sciences Lahore; Pakistan. Primary measure: First-Pass Success Rate of Ultrasound-Guided Internal Jugular Vein Cannulation. 3 linked papers (newest 2022).
Registry record
As filed in ClinicalTrials.gov.
- Title
- Comparison of Short-Axis and Long-Axis Internal Jugular Vein Cannulation for First-Pass Success
- Official title
- Comparison Between Short Axis and Long Axis For Cannulation Of Internal Jugular Vein in Terms Of First Pass Success
- Lead sponsor
- University of Health Sciences Lahore
- Phase
- Not applicable
- Overall status
- Not yet recruiting
- Start date
- October 31, 2026
- Completion date
- April 30, 2027
- Enrollment
- 10 (estimated)
- Sites
- 1
Conditions
As the registry lists them.
cannulation of internal jugular vein
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 25 Years
- Maximum age
- 70 Years
- Healthy volunteers
- No
- Study type
- Interventional
- Sites
- 1
- Countries
- Pakistan
- Lead sponsor
- University of Health Sciences Lahore
Arms
As registered; 2 arms.
| Arm | Type | Interventions |
|---|---|---|
| Group A (Short-Axis Approach) | Active comparator | Short-Axis Ultrasound-Guided Internal Jugular Vein Cannulation |
Show registry wordingIn this approach, IJV will be visualized by placing the transducer in a transverse orientation on the patient neck at the level of the cricoid cartilage. The needle will be inserted at 60° to the vertical and will be advanced toward the vein employing gentle aspiration on the attached syringe. Entry to the vein will be confirmed by visualizing indentation of the anterior wall of the vein followed by blood in the syringe and by visualizing the tip of the needle inside the vein. Guide wire will be passed followed by dilator insertion and finally central vein line. | ||
| Group B (Long-Axis Approach) | Active comparator | Long-Axis Ultrasound-Guided Internal Jugular Vein Cannulation |
Show registry wordingIn this approach, the probe will be centered on the IJV and rotated through 90° in a clockwise direction resulting in long axis image of the vein. The needle insertion point will be directly beneath the most proximal end of the ultrasound probe. The needle will be inserted at 30° to the vertical and will be advanced toward the vein employing gentle aspiration. Entry to the vein will be confirmed by visualizing needle entry into the vein followed by aspiration of blood in the syringe. Guide wire will be inserted followed by dilator insertion and finally central vein line. | ||
Primary endpoints
Registered primary outcome measures; 1 primary.
| Measure | Time frame |
|---|---|
| First-Pass Success Rate of Ultrasound-Guided Internal Jugular Vein Cannulation | Assessed during the cannulation procedure (within 5 minutes of initiation of cannulation). |
Show registry wordingFirst-pass success rate of ultrasound-guided internal jugular vein cannulation, defined as successful venous cannulation with a single skin puncture and needle pass. | |
Papers
PubMed papers this trial cites; 3 papers, results papers first, then newest first.
Lead sponsor's other trials
University of Health Sciences Lahore, most recent start first.
+77 more trials See the organization page