Wearable Blood-Pressure Monitoring Comparison Study

NCT07719660 is registered in ClinicalTrials.gov with Technische Universität Dresden as lead sponsor.

NCT NCT07719660 Recruiting Observational 120 participants (estimated) Started 2026 2 sites

Follow this trial by email Email me the PDF

Get the NCT07719660 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Recruiting, started July 2026. Observational study, 120 participants (estimated). Lead sponsor Technische Universität Dresden; Germany, Italy. Primary measure: Agreement of wearable blood pressure measurement methods with clinical reference measurements.

How it compares

1,307 similar trials: same condition (Hypertension) and phase

Enrollment

This trial
120
Middle half
100 to 2,000
Median
325
Trials with a value
1,142

Months from start to completion

This trial
17.4
Middle half
14.1 to 61
Median
33
Trials with a value
1,232

Sites

This trial
2
Middle half
1 to 1
Median
1
Trials with a value
997
Posted results or a linked paper 49% 639 of 1,307 similar trials; this trial: no

Registry record

As filed in ClinicalTrials.gov.

Title
Wearable Blood-Pressure Monitoring Comparison Study
Official title
Wearable Blood-Pressure Monitoring Comparison Study (WBPMCS)
Lead sponsor
Technische Universität Dresden
Phase
Observational
Overall status
Recruiting
Start date
July 20, 2026
Completion date
December 31, 2027
Enrollment
120 (estimated)
Sites
2

Conditions

MeSH condition names; the registry's own terms follow.

Hypertension

Registry terms: blood pressure monitoring, cuff, photoplethysmography, wearable devices

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
21 Years
Maximum age
85 Years
Healthy volunteers
Yes
Study type
Observational
Sites
2
Countries
Germany, Italy
Lead sponsor
Technische Universität Dresden

Arms

As registered; 2 arms.

Registered arms
Arm Type Interventions
Cohort at general ward
Cohort at ICU

Primary endpoints

Registered primary outcome measures; 1 primary.

Registered primary endpoints
Measure Time frame
Agreement of wearable blood pressure measurement methods with clinical reference measurements General ward: At each measurement session on study days 1, 2, and 3. ICU: At measurement session on study day 1, approx. 2 hours after device calibration
Show registry wording

The mean difference and standard deviation of the differences in systolic and diastolic blood pressure, expressed in mmHg, between each investigated wearable blood pressure measurement method and the corresponding reference method.

Lead sponsor's other trials

Technische Universität Dresden, most recent start first.

Similar trials

Same condition (Hypertension) and phase, most recent start first.