Clinical trial
IOL Power Formula Prediction Accuracy at the Extremes of Axial Length: A Prospective Outcome Verification Study
NCT07724795 is registered in ClinicalTrials.gov with Vienna Hospital Association as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started August 2026. Observational study, 200 participants (estimated). Lead sponsor Vienna Hospital Association; Austria. Primary measure: Spherical equivalent prediction error (SE-PE) across eight IOL power formulas, compared within each axial...
How it compares
26 similar trials: same condition (Pseudophakia) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- IOL Power Formula Prediction Accuracy at the Extremes of Axial Length: A Prospective Outcome Verification Study
- Official title
- Clinical Outcomes of Formula-dependent IOL Power Selection at the Extremes of Axial Length: a Cross-sectional Outcome Verification of Seven ESCRS-hosted Formulas and the Ladas Super Formula 2.0 in Short (<22.0 mm) and Long (>26.0 mm) Eyes Using Refractive, Biometric, and Tomographic Assessment
- Lead sponsor
- Vienna Hospital Association
- Phase
- Observational
- Overall status
- Not yet recruiting
- Start date
- August 1, 2026
- Completion date
- July 1, 2027
- Enrollment
- 200 (estimated)
- Sites
- 1
Conditions
MeSH condition names; the registry's own terms follow.
Pseudophakia, Refractive Errors
Registry terms: refractive error
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Healthy volunteers
- No
- Study type
- Observational
- Sites
- 1
- Countries
- Austria
- Lead sponsor
- Vienna Hospital Association
Arms
As registered; 2 arms.
| Arm | Type | Interventions |
|---|---|---|
| Short axial length stratum (AL < 22.0 mm) | Standardized postoperative outcome visit | |
Show registry wordingPseudophakic eyes with a preoperative axial length below 22.0 mm that received a spherical monofocal IOL. These eyes undergo the standardized postoperative outcome visit; the measured spherical equivalent is compared with each formula's prediction for the implanted IOL power. | ||
| Long axial length stratum (AL > 26.0 mm) | Standardized postoperative outcome visit | |
Show registry wordingPseudophakic eyes with a preoperative axial length above 26.0 mm that received a spherical monofocal IOL. These eyes undergo the standardized postoperative outcome visit (including obligatory macular OCT); the measured spherical equivalent is compared with each formula's prediction for the implanted IOL power. | ||
Primary endpoints
Registered primary outcome measures; 1 primary.
| Measure | Time frame |
|---|---|
| Spherical equivalent prediction error (SE-PE) across eight IOL power formulas, compared within each axial length stratum | Single study visit, at least 3 months after cataract surgery |
Show registry wordingFor each eye, SE-PE is calculated as the measured postoperative spherical equivalent (standardized manifest refraction) minus the residual spherical equivalent predicted by each formula for the actually implanted IOL power step. The absolute prediction error (\|SE-PE\|) is compared globally across the eight formulas (Barrett Universal II, Cooke K6, EVO 2.0, Hill-RBF 3.0, Hoffer QST, Kane, PEARL-DGS, Ladas Super Formula 2.0) using the Friedman test, with post-hoc pairwise Wilcoxon signed-rank tests (Holm-corrected, 28 formula pairs), performed separately in the short (AL \< 22.0 mm) and long (AL \> 26.0 mm) strata. The primary accuracy metric per formula is the median absolute prediction error (MedAE). | |
Lead sponsor's other trials
Vienna Hospital Association, most recent start first.
+5 more trials
Similar trials
Same condition (Pseudophakia) and phase, most recent start first.
+21 more trials See the condition page