Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

IOL Power Formula Prediction Accuracy at the Extremes of Axial Length: A Prospective Outcome Verification Study

NCT07724795 is registered in ClinicalTrials.gov with Vienna Hospital Association as lead sponsor.

NCT NCT07724795 Not yet recruiting Observational 200 participants (estimated) Started 2026 1 site

Follow this trial by email Email me the PDF

Get the NCT07724795 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Not yet recruiting, started August 2026. Observational study, 200 participants (estimated). Lead sponsor Vienna Hospital Association; Austria. Primary measure: Spherical equivalent prediction error (SE-PE) across eight IOL power formulas, compared within each axial...

How it compares

26 similar trials: same condition (Pseudophakia) and phase

Enrollment

This trial
200
Middle half
32 to 118
Median
57
Trials with a value
26

Months from start to completion

This trial
11
Middle half
5 to 16.6
Median
11.1
Trials with a value
25

Sites

This trial
1
Middle half
1 to 1
Median
1
Trials with a value
25
Posted results or a linked paper 38% 10 of 26 similar trials; this trial: no

Registry record

As filed in ClinicalTrials.gov.

Title
IOL Power Formula Prediction Accuracy at the Extremes of Axial Length: A Prospective Outcome Verification Study
Official title
Clinical Outcomes of Formula-dependent IOL Power Selection at the Extremes of Axial Length: a Cross-sectional Outcome Verification of Seven ESCRS-hosted Formulas and the Ladas Super Formula 2.0 in Short (<22.0 mm) and Long (>26.0 mm) Eyes Using Refractive, Biometric, and Tomographic Assessment
Lead sponsor
Vienna Hospital Association
Phase
Observational
Overall status
Not yet recruiting
Start date
August 1, 2026
Completion date
July 1, 2027
Enrollment
200 (estimated)
Sites
1

Conditions

MeSH condition names; the registry's own terms follow.

Pseudophakia, Refractive Errors

Registry terms: refractive error

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Healthy volunteers
No
Study type
Observational
Sites
1
Countries
Austria
Lead sponsor
Vienna Hospital Association

Arms

As registered; 2 arms.

Registered arms
Arm Type Interventions
Short axial length stratum (AL < 22.0 mm) Standardized postoperative outcome visit
Show registry wording

Pseudophakic eyes with a preoperative axial length below 22.0 mm that received a spherical monofocal IOL. These eyes undergo the standardized postoperative outcome visit; the measured spherical equivalent is compared with each formula's prediction for the implanted IOL power.

Long axial length stratum (AL > 26.0 mm) Standardized postoperative outcome visit
Show registry wording

Pseudophakic eyes with a preoperative axial length above 26.0 mm that received a spherical monofocal IOL. These eyes undergo the standardized postoperative outcome visit (including obligatory macular OCT); the measured spherical equivalent is compared with each formula's prediction for the implanted IOL power.

Primary endpoints

Registered primary outcome measures; 1 primary.

Registered primary endpoints
Measure Time frame
Spherical equivalent prediction error (SE-PE) across eight IOL power formulas, compared within each axial length stratum Single study visit, at least 3 months after cataract surgery
Show registry wording

For each eye, SE-PE is calculated as the measured postoperative spherical equivalent (standardized manifest refraction) minus the residual spherical equivalent predicted by each formula for the actually implanted IOL power step. The absolute prediction error (\|SE-PE\|) is compared globally across the eight formulas (Barrett Universal II, Cooke K6, EVO 2.0, Hill-RBF 3.0, Hoffer QST, Kane, PEARL-DGS, Ladas Super Formula 2.0) using the Friedman test, with post-hoc pairwise Wilcoxon signed-rank tests (Holm-corrected, 28 formula pairs), performed separately in the short (AL \< 22.0 mm) and long (AL \> 26.0 mm) strata. The primary accuracy metric per formula is the median absolute prediction error (MedAE).

Lead sponsor's other trials

Vienna Hospital Association, most recent start first.

+5 more trials

Similar trials

Same condition (Pseudophakia) and phase, most recent start first.