Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

Beat-to-beat Evaluation of Atrial Pacing to Test Fluid Responsiveness

NCT07730242 is registered in ClinicalTrials.gov with Maastricht University Medical Center as lead sponsor.

NCT NCT07730242 Not yet recruiting Not applicable 18 participants (estimated) Started 2027

Follow this trial by email Email me the PDF

Get the NCT07730242 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Not yet recruiting, started January 2027. Interventional study, 18 participants (estimated). Lead sponsor Maastricht University Medical Center. Primary measure: change in stroke volume measured before and after fluid administration in response to beat-to-beat atrial...

Registry record

As filed in ClinicalTrials.gov.

Title
Beat-to-beat Evaluation of Atrial Pacing to Test Fluid Responsiveness
Official title
BEAT- FR Beat-to-beat Evaluation of Atrial Pacing to Test Fluid Responsiveness
Lead sponsor
Maastricht University Medical Center
Phase
Not applicable
Overall status
Not yet recruiting
Start date
January 31, 2027
Completion date
January 31, 2029
Enrollment
18 (estimated)
Sites
Not reported

Conditions

As the registry lists them.

evaluate whether beat-to-beat ramped atrial pacing is related to fluid responsiveness in postcardiac surgery patients

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
18 Years
Healthy volunteers
No
Study type
Interventional
Lead sponsor
Maastricht University Medical Center

Arms

As registered; 1 arm.

Registered arms
Arm Type Interventions
Standard atrial pacing (80-120 bpm) before and after a routine 500 mL fluid bolus. Experimental Pacing protocol via routinely placed surgical pacemaker wire
Show registry wording

No therapeutic intervention will take place. A pacemaker wire is routinely placed by the cardiac surgeon after the surgery, as part of the standard care that occurs with every surgery. As part of the study protocol, an atrial pacing protocol is performed, starting with pacing at 80 bpm, then increasing by 10 beats per minute until reaching 120 bpm, followed by a gradual decrease back to 80 bpm. This protocol is repeated after the administration of the 500 mL fluid bolus.

Primary endpoints

Registered primary outcome measures; 1 primary.

Registered primary endpoints
Measure Time frame
change in stroke volume measured before and after fluid administration in response to beat-to-beat atrial pacing. On day 1
Show registry wording

The main study parameter is the change in stroke volume measured before and after fluid administration in response to beat-to-beat atrial pacing. Stroke volume will be assessed using VTI of the LVOT via transthoracic echocardiography. This change will be compared between fluid responders (defined as a ≥10% increase in stroke volume following fluid administration) and non-responders to assess the predictive accuracy of the pacing protocol.

Lead sponsor's other trials

Maastricht University Medical Center, most recent start first.