Clinical trial
Real-World Validation for Less-Disturbing Ambulatory Blood Pressure Monitoring (ABPM) in Malaysia Using Huawei Wearables
NCT07790978 is registered in ClinicalTrials.gov with Sunway University as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started December 2026. Observational study, 500 participants (estimated). Lead sponsor Sunway University; Malaysia. Primary measures: Mean Difference in Blood Pressure Measured by Reduced-Frequency Smartwatch Schedule Versus Standard 24-Hour...; Mean Absolute Error (MAE) of Blood Pressure Readings Between Reduced-Frequency Smartwatch Schedule... and 2 more. 5 linked papers (newest 2026).
How it compares
1,307 similar trials: same condition (Hypertension) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- Real-World Validation for Less-Disturbing Ambulatory Blood Pressure Monitoring (ABPM) in Malaysia Using Huawei Wearables
- Official title
- Not reported
- Lead sponsor
- Sunway University
- Phase
- Observational
- Overall status
- Not yet recruiting
- Start date
- December 1, 2026
- Completion date
- December 31, 2028
- Enrollment
- 500 (estimated)
- Sites
- 1
Conditions
MeSH condition names; the registry's own terms follow.
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 18 Years
- Healthy volunteers
- Yes
- Study type
- Observational
- Sites
- 1
- Countries
- Malaysia
- Lead sponsor
- Sunway University
Arms
As registered; 4 arms.
| Arm | Type | Interventions |
|---|---|---|
| Normotensive Cohort | ||
Show registry wordingAdult participants with normal blood pressure (defined as blood pressure \< 135/85 mmHg; n = 10) who undergo simultaneous standard 24-hour ABPM and Huawei smartwatch monitoring. | ||
| Undiagnosed Elevated Blood Pressure Cohort | ||
Show registry wordingAdult participants with undiagnosed elevated blood pressure (defined as blood pressure \> 135/85 mmHg; n = 20) who undergo simultaneous standard 24-hour ABPM and Huawei smartwatch monitoring. | ||
| Documented Hypertensive Cohort | ||
Show registry wordingAdult participants with documented or self-reported hypertension (n = 20) who undergo simultaneous standard 24-hour ABPM and Huawei smartwatch monitoring. | ||
| Screening Population | ||
Show registry wordingGeneral adult participants recruited across Malaysia who enroll via the Huawei Research Platform app to provide continuous wearable ambulatory blood pressure and physiological data and complete baseline health assessments over the study period. | ||
Primary endpoints
Registered primary outcome measures; 4 primary.
| Measure | Time frame |
|---|---|
| Mean Difference in Blood Pressure Measured by Reduced-Frequency Smartwatch Schedule Versus Standard 24-Hour Ambulatory Blood Pressure Monitor (ABPM) | Month 13 through Month 18 (during clinical ABPM validation testing). |
Show registry wordingMeasure Description: Mean blood pressure difference (bias) for 24-hour, daytime, and night-time periods calculated by subtracting reference 24-hour ABPM values (SpaceLabs/Mobil-O-Graph cuff monitor) from reduced-frequency Huawei smartwatch ABPM values (7-measurement schedule). Unit of Measure: mmHg | |
| Mean Absolute Error (MAE) of Blood Pressure Readings Between Reduced-Frequency Smartwatch Schedule and Standard 24-Hour ABPM | Month 13 through Month 18. |
Show registry wordingMeasure Description: The average absolute difference between blood pressure readings obtained from the reduced-frequency Huawei smartwatch schedule and the standard 24-hour cuff-based ABPM monitor. Unit of Measure: mmHg | |
| Root Mean Square Error (RMSE) of Blood Pressure Readings Between Reduced-Frequency Smartwatch Schedule and Standard 24-Hour ABPM | Month 13 through Month 18 |
Show registry wordingMeasure Description: The root mean square error evaluating agreement between blood pressure values recorded by the reduced-frequency Huawei smartwatch schedule and the standard 24-hour cuff-based ABPM monitor. Unit of Measure: mmHg | |
| Intraclass Correlation Coefficient (ICC) of Blood Pressure Measurements Between Reduced-Frequency Smartwatch Schedule and Standard 24-Hour ABPM | Month 13 through Month 18 |
Show registry wordingMeasure Description: Agreement reliability calculated using absolute-agreement two-way random-effects ICC comparing reduced-frequency Huawei smartwatch blood pressure estimates against full 24-hour ABPM readings. Unit of Measure: Intraclass Correlation Coefficient (score ranging from -1.0 to +1.0) | |
Papers
PubMed papers this trial cites; 5 papers, results papers first, then newest first.
Lead sponsor's other trials
Sunway University, most recent start first.
+5 more trials See the organization page
Similar trials
Same condition (Hypertension) and phase, most recent start first.
+1,302 more trials See the condition page