Clinical trial
SYMmetric Valve fraME Expansion To Reduce hYpoattenuated Leaflet Thickening After Balloon-expandable TAVI: the SYMMETRY Trial
NCT07872020 is registered in ClinicalTrials.gov with Erasmus Medical Center as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Recruiting, started October 2026. Interventional study, 422 participants (estimated). Lead sponsor Erasmus Medical Center; Netherlands, Germany. Primary measures: Hypoattenuated Leaflet Thickening (HALT); Co-primary: VARC-3-defined safety. 17 linked papers (newest 2026).
How it compares
77 similar trials: same condition (Aortic Valve Insufficiency) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- SYMmetric Valve fraME Expansion To Reduce hYpoattenuated Leaflet Thickening After Balloon-expandable TAVI: the SYMMETRY Trial
- Official title
- Not reported
- Lead sponsor
- Erasmus Medical Center
- Phase
- Not applicable
- Overall status
- Recruiting
- Start date
- October 26, 2026
- Completion date
- November 1, 2033
- Enrollment
- 422 (estimated)
- Sites
- 5
Conditions
MeSH condition names; the registry's own terms follow.
Aortic Valve Insufficiency, Aortic Valve Stenosis
Registry terms: aortic valve stenosis and/or insufficiency, hypoattenuated leaflet thickening, transcatheter aortic valve replacement, valve expansion
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 70 Years
- Healthy volunteers
- No
- Study type
- Interventional
- Sites
- 5
- Countries
- Netherlands, Germany
- Lead sponsor
- Erasmus Medical Center
Arms
As registered; 2 arms.
| Arm | Type | Interventions |
|---|---|---|
| Double-TAP post-dilatation | Active comparator | Double-TAP post-dilatation |
| No post-dilatation | No intervention |
Primary endpoints
Registered primary outcome measures; 2 primary.
| Measure | Time frame |
|---|---|
| Hypoattenuated Leaflet Thickening (HALT) | 30 days |
Show registry wordingHALT (at least one thickened TAV leaflet involving \> 25% of the leaflet curvilinear dimension as assessed at cardiac CT) | |
| Co-primary: VARC-3-defined safety | 30 days |
Show registry wordingComposite of 1) freedom from all-cause mortality; 2) freedom from all new stroke; 3) freedom from VARC type 2 to 4 bleeding; 4) freedom from major vascular, access-related, or cardiac structural complications; 5) freedom from acute kidney injury stage 3 or 4; 6) freedom from moderate or severe aortic regurgitation; 7) freedom from new permanent pacemaker implantation caused by procedure related conduction abnormalities; and 8) freedom from surgery or intervention related to the device in accordance with the third Valve Academic Research Consortium (VARC-3) criteria at 30 days. | |
Papers
PubMed papers this trial cites; 17 papers, results papers first, then newest first.
+12 more papers
Lead sponsor's other trials
Erasmus Medical Center, most recent start first.
+473 more trials
Similar trials
Same condition (Aortic Valve Insufficiency) and phase, most recent start first.
+72 more trials See the condition page