Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

Performance Evaluation of the OCUTOP Hand-held Corneal Topographer

NCT07895849 is registered in ClinicalTrials.gov with University of Plymouth as lead sponsor.

NCT NCT07895849 Not yet recruiting Not applicable 150 participants (estimated) Started 2027 2 sites

Follow this trial by email Email me the PDF

Get the NCT07895849 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Not yet recruiting, started January 2027. Interventional study, 150 participants (estimated). Lead sponsor University of Plymouth; United Kingdom. Primary measures: Agreement between the OCUTOP and the reference instrument for central simulated mean keratometry (K-mean); Agreement between the OCUTOP and the reference instrument for first non-invasive tear break-up time... and 2 more.

How it compares

113 similar trials: same condition (Keratoconus) and phase

Enrollment

This trial
150
Middle half
24 to 62
Median
40
Trials with a value
112

Months from start to completion

This trial
1.9
Middle half
16.8 to 49.5
Median
32
Trials with a value
111

Sites

This trial
2
Middle half
1 to 1
Median
1
Trials with a value
95
Posted results or a linked paper 45% 51 of 113 similar trials; this trial: no

Registry record

As filed in ClinicalTrials.gov.

Title
Performance Evaluation of the OCUTOP Hand-held Corneal Topographer
Official title
Performance Evaluation of the OCUTOP Corneal Topographer With OCUGRAPH Software: Agreement With Reference Instruments, Repeatability and Safety in an Unselected Adult Clinic Population
Lead sponsor
University of Plymouth
Phase
Not applicable
Overall status
Not yet recruiting
Start date
January 31, 2027
Completion date
March 31, 2027
Enrollment
150 (estimated)
Sites
2

Conditions

MeSH condition names; the registry's own terms follow.

Dry Eye Syndromes, Keratoconus

Registry terms: corneal topography, healthy volunteers

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
18 Years
Healthy volunteers
Yes
Study type
Interventional
Sites
2
Countries
United Kingdom
Lead sponsor
University of Plymouth

Arms

As registered; 1 arm.

Registered arms
Arm Type Interventions
OCUTOP and reference instruments Experimental OCUTOP hand-held corneal topographer with OCUGRAPH software, Reference instrument measurement (corneal topography and tear-film assessment)
Show registry wording

All participants. At a single visit, both eyes are measured with the OCUTOP corneal topographer (OCUGRAPH software) and with the site reference instruments (Pentacam HR, Keratograph 5M and Medmont E300 at Site 01; Myah at Site 02), in a randomised order of instrument blocks and eyes, with a rest of at least 5 minutes between blocks. Participants complete two short questionnaires. No treatment is given and there is no follow-up.

Primary endpoints

Registered primary outcome measures; 4 primary.

Registered primary endpoints
Measure Time frame
Agreement between the OCUTOP and the reference instrument for central simulated mean keratometry (K-mean) Single study visit (Day 1)
Show registry wording

Mean paired difference (OCUTOP minus reference, dioptres) with 95% confidence interval, and Bland-Altman 95% limits of agreement with their 95% confidence intervals, in the analysis eye, pooled across sites and by site. Reference: Pentacam HR (Site 01), Myah (Site 02).

Agreement between the OCUTOP and the reference instrument for first non-invasive tear break-up time (NIBUT-first) Single study visit (Day 1)
Show registry wording

Mean paired difference (OCUTOP minus reference, seconds) with 95% confidence interval, and Bland-Altman 95% limits of agreement with their 95% confidence intervals, in the analysis eye, pooled across sites and by site. Reference: Keratograph 5M (Site 01), Myah (Site 02).

Agreement between the OCUTOP and the reference instrument for average non-invasive tear break-up time (NIBUT-average) Single study visit (Day 1)
Show registry wording

Mean paired difference (OCUTOP minus reference, seconds) with 95% confidence interval, and Bland-Altman 95% limits of agreement with their 95% confidence intervals, in the analysis eye, pooled across sites and by site. Reference: Keratograph 5M (Site 01), Myah (Site 02).

Agreement between the OCUTOP and the reference instrument for central lower tear meniscus height (TMH) Single study visit (Day 1)
Show registry wording

Mean paired difference (OCUTOP minus reference, millimetres) with 95% confidence interval, and Bland-Altman 95% limits of agreement with their 95% confidence intervals, in the analysis eye, pooled across sites and by site. Reference: Keratograph 5M (Site 01), Myah (Site 02).

Lead sponsor's other trials

University of Plymouth, most recent start first.

Similar trials

Same condition (Keratoconus) and phase, most recent start first.