Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

The Role of Simulation Fidelity in Early Surgical Skills Education

NCT07899684 is registered in ClinicalTrials.gov with Medical University of Lodz as lead sponsor.

NCT NCT07899684 Completed Not applicable 131 participants (actual) Started 2025 3 sites

Follow this trial by email Email me the PDF

Get the NCT07899684 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Completed, November 2025. Interventional study, 131 participants (actual). Lead sponsor Medical University of Lodz; Poland. Primary measures: Trainee-reported outcomes; Expert-rated technical outcomes.

Registry record

As filed in ClinicalTrials.gov.

Title
The Role of Simulation Fidelity in Early Surgical Skills Education
Official title
Not reported
Lead sponsor
Medical University of Lodz
Phase
Not applicable
Overall status
Completed
Start date
May 20, 2025
Completion date
November 14, 2025
Enrollment
131 (actual)
Sites
3

Conditions

As the registry lists them.

medical education, medical education assessment, medical student, simulation training

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Healthy volunteers
Yes
Study type
Interventional
Sites
3
Countries
Poland
Lead sponsor
Medical University of Lodz

Arms

As registered; 2 arms.

Registered arms
Arm Type Interventions
Medical students (various materials) Active comparator Suture skills retention
Show registry wording

Medical students with no prior suturing experience and no known allergies to the materials used who are willing to participate in suturing on porcine skin, banana, chicken, or orange in Round 1, then on silicone model in Round 2.

Medical students (silicone only) Sham comparator Suture skills retention
Show registry wording

Medical students with no prior suturing experience and no known allergies to the materials used who are willing to participate in suturing on a silicone model in Round 1, then on a silicone model in Round 2.

Primary endpoints

Registered primary outcome measures; 2 primary.

Registered primary endpoints
Measure Time frame
Trainee-reported outcomes 1 day
Show registry wording

Immediately after practice, trainees complete a questionnaire rating the training material and the learning experience. Four items are measured on a 5-point Likert scale (1-5): material comfort/usability, perceived realism (similarity to human skin), perceived understanding of basic suturing principles, and perceived development of practical skills. Additionally, trainees rate their confidence in placing sutures on a 0-10 numeric scale.

Expert-rated technical outcomes 1 day
Show registry wording

Experienced surgeons evaluate students' sutures across multiple domains, each scored on a 1-5 scale (1 = worst, 5 = best). For students who do not complete the task, a score of "0" is recorded, and the result is excluded from the qualitative analysis.

Technical endpoints are analysed separately for simple interrupted domains, vertical mattress domains, and global composite scores, defined as the mean across available domains within a suture type. Composite scores will first be calculated at the participant level as the mean across available domains. Group-level summaries will be presented as medians with interquartile ranges (IQR) due to the non-normal distribution of scores.

Lead sponsor's other trials

Medical University of Lodz, most recent start first.