Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

Impact of High Thoracic Paravertebral Block on Diaphragmatic Function: a Prospective Study

NCT07907692 is registered in ClinicalTrials.gov with Ciusss de L'Est de l'Île de Montréal as lead sponsor.

NCT NCT07907692 Not yet recruiting Not applicable 40 participants (estimated) Started 2026 1 site

Follow this trial by email Email me the PDF

Get the NCT07907692 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Not yet recruiting, started September 2026. Interventional study, 40 participants (estimated). Lead sponsor Ciusss de L'Est de l'Île de Montréal; Canada. Primary measure: Incidence of ipsilateral hemidiaphragmatic dysfunction determined by diaphragm ultrasonography.

Registry record

As filed in ClinicalTrials.gov.

Title
Impact of High Thoracic Paravertebral Block on Diaphragmatic Function: a Prospective Study
Official title
Not reported
Lead sponsor
Ciusss de L'Est de l'Île de Montréal
Phase
Not applicable
Overall status
Not yet recruiting
Start date
September 30, 2026
Completion date
May 31, 2027
Enrollment
40 (estimated)
Sites
1

Conditions

As the registry lists them.

breast cancer surgery, breast cancer surgery pain, hemidiaphragmatic paralysis

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
18 Years
Maximum age
80 Years
Healthy volunteers
No
Study type
Interventional
Sites
1
Countries
Canada
Lead sponsor
Ciusss de L'Est de l'Île de Montréal

Arms

As registered; 1 arm.

Registered arms
Arm Type Interventions
High thoracic paravertebral block Experimental High thoracic paravertebral block
Show registry wording

Participants undergoing unilateral oncologic breast surgery will receive an ultrasound-guided high thoracic paravertebral block using a standardized two-injection technique. After baseline diaphragmatic ultrasound assessment, a regional anesthesiologist will perform the block at the T1-T2 level and at a second thoracic level selected according to the surgical site using a total of 30 mL of local anesthetic (15 mL per injection). The block will be performed with the ultrasound transducer in the sagittal position about 2.5 to 3 centimeters (cm) lateral to the spinous process using a caudal to cranial in-plane needle approach. The thoracic vertebral levels will be identified by finding the first rib under ultrasound guidance and counting down levels appropriately. The needle (80 mm 22-gauge echogenic SonoPlex needle from Pajunk) will be introduced in-plane in a caudal to cranial. Diaphragmatic ultrasound measurements will be repeated in the post-anesthesia care unit following surgery.

Primary endpoints

Registered primary outcome measures; 1 primary.

Registered primary endpoints
Measure Time frame
Incidence of ipsilateral hemidiaphragmatic dysfunction determined by diaphragm ultrasonography Postoperative assessment in the PACU, approximately 1-3 hours after block placement.
Show registry wording

The incidence of ipsilateral hemidiaphragmatic paralysis following high thoracic paravertebral block, assessed by diaphragm ultrasonography using the diaphragmatic thickening fraction (DTF).

Lead sponsor's other trials

Ciusss de L'Est de l'Île de Montréal, most recent start first.