Clinical trial
The Evaluation of User Experience With FARAVIEW™ Technology of the OPAL HDx™ Mapping System When Used With the FARAWAVE NAV™ ULTRA Pulsed Field Ablation Catheter in the Treatment of Atrial Fibrillation
NCT07925359 is registered in ClinicalTrials.gov with Boston Scientific Corporation as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started January 2027. Interventional study, 200 participants (estimated). Lead sponsor Boston Scientific Corporation; Croatia, Czechia, France. Primary measures: Incidence of device-related or procedure-related events of a serious nature; Acute Procedural Success for PV and LAPW Isolation and 2 more.
How it compares
1,663 similar trials: same condition (Atrial Fibrillation) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- The Evaluation of User Experience With FARAVIEW™ Technology of the OPAL HDx™ Mapping System When Used With the FARAWAVE NAV™ ULTRA Pulsed Field Ablation Catheter in the Treatment of Atrial Fibrillation
- Official title
- Not reported
- Lead sponsor
- Boston Scientific Corporation
- Phase
- Not applicable
- Overall status
- Not yet recruiting
- Start date
- January 20, 2027
- Completion date
- October 31, 2027
- Enrollment
- 200 (estimated)
- Sites
- 3
Conditions
MeSH condition names; the registry's own terms follow.
Registry terms: atrial fibrillation (af), farapulse, paroxysmal af, persistent atrial fibrillation (persaf)
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 18 Years
- Healthy volunteers
- No
- Study type
- Interventional
- Sites
- 3
- Countries
- Croatia, Czechia, France
- Lead sponsor
- Boston Scientific Corporation
Arms
As registered; 1 arm.
| Arm | Type | Interventions |
|---|---|---|
| Treatment Group: Ablation Procedure | Other | Ablation Treatment with FARAPULSE™ Pulsed Field Ablation (PFA) System and OPAL HDx™ Mapping System |
Show registry wordingUp to approximately 200 subjects scheduled to undergo catheter-based endocardial mapping and ablation in the treatment of paroxysmal or persistent atrial fibrillation (de novo or redo subject) with the new and modified components of the FARAPULSE™ Pulsed Field Ablation (PFA) System when used with the OPAL HDx™ Mapping System. | ||
Primary endpoints
Registered primary outcome measures; 4 primary.
| Measure | Time frame |
|---|---|
| Incidence of device-related or procedure-related events of a serious nature | Day 0 (ablation procedure) - Day 7; Day 0 - Day 30; Day 0 - Day 60 |
Show registry wordingSafety will be assessed for subjects who undergo ablation using the investigational system configuration of the FARAPULSE™ PFA System during the Index Procedure or any repeat PFA procedure using the investigational system configuration. Safety will be characterized descriptively by the incidence of device-related or procedure-related events of a serious nature with onset dates within the follow-up intervals: Day 0-7; Day 0-30; Day 0-60. | |
| Acute Procedural Success for PV and LAPW Isolation | At the end of the ablation procedure |
Show registry wording* The proportion of de novo subjects that achieve acute procedural success (APS) defined as percutaneous endocardial creation of a complete, electrically isolating set of lesions around the ostia of the pulmonary veins (PV) and left atrial posterior wall (LAPW) during the index procedure.
APS will be clinically assessed by entrance and/or exit block or confirmed by electroanatomical mapping for the PVs and by the site's standard of care method for LAPW. Redo subjects not requiring PV ablation will be excluded from the evaluation of acute PV isolation success. | |
| Acute Procedural Success for CTI, MI and SVC Ablation | At the end of the ablation procedure |
Show registry wording* The proportion of subjects undergoing cavotricuspid (CTI) ablation using the FARAWAVE NAV Ultra PFA Catheter in whom bidirectional conduction block across the CTI line is achieved during the Index procedure.
Acute procedural success for CTI, MI, and SVC ablation lesions will be assessed according to each study site's standard-of-care method. | |
| Acute Procedural Success - Timing | At the end of the ablation procedure |
Show registry wordingAcute procedural effectiveness will be evaluated using procedural performance measures, including but not limited ablation time per lesion set, total procedure time, fluoroscopy time, left atrial dwell time, and transseptal access timing, assessed during the Index Procedure. | |