Clinical trial
Function-Friendly Semi-Fowler Positioning for Coronary Angiography and PCI
NCT07944716 is registered in ClinicalTrials.gov with Shanghai Zhongshan Hospital as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started November 2026. Interventional study, 10 participants (estimated). Lead sponsor Shanghai Zhongshan Hospital; China. Primary measures: Proportion of Participants With Coronary Angiography (CAG) Technical Success; Proportion of Participants With Percutaneous Coronary Intervention (PCI) Technical Success and 1 more.
How it compares
417 similar trials: same condition (Coronary Disease) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- Function-Friendly Semi-Fowler Positioning for Coronary Angiography and PCI
- Official title
- Pilot Study on the Feasibility and Safety of Function-Friendly Semi-Fowler Positioning in Coronary Angiography and Percutaneous Coronary Intervention
- Lead sponsor
- Shanghai Zhongshan Hospital
- Phase
- Not applicable
- Overall status
- Not yet recruiting
- Start date
- November 25, 2026
- Completion date
- November 30, 2028
- Enrollment
- 10 (estimated)
- Sites
- 1
Conditions
MeSH condition names; the registry's own terms follow.
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 18 Years
- Maximum age
- 75 Years
- Healthy volunteers
- No
- Study type
- Interventional
- Sites
- 1
- Countries
- China
- Lead sponsor
- Shanghai Zhongshan Hospital
Arms
As registered; 1 arm.
| Arm | Type | Interventions |
|---|---|---|
| Function-Friendly Semi-Fowler Positioning | Experimental | Function-Friendly Semi-Fowler Positioning |
Show registry wordingAll participants receive the same positioning intervention during elective transradial CAG and, if clinically indicated, simple PCI. The procedure table is raised to a default head elevation of 60 degrees, with continuous ECG, blood pressure, and oxygen saturation monitoring. If predefined safety concerns occur, the table angle is lowered or the participant is returned to 0-degree supine and usual clinical care is provided. | ||
Primary endpoints
Registered primary outcome measures; 3 primary.
| Measure | Time frame |
|---|---|
| Proportion of Participants With Coronary Angiography (CAG) Technical Success | During the CAG procedure |
Show registry wordingThe number of participants undergoing CAG who complete the planned CAG in the prespecified semi-Fowler position without position-related unplanned return to supine or substantial angle reduction, procedure discontinuation, access-site change, missing key projections, or participant/equipment collision, and whose images are independently confirmed to be diagnostic, divided by the number of participants undergoing CAG. | |
| Proportion of Participants With Percutaneous Coronary Intervention (PCI) Technical Success | During the PCI procedure |
Show registry wordingAmong participants who undergo PCI, the proportion who complete planned device delivery, treatment, and withdrawal while meeting the protocol-defined positioning and safety requirements. PCI success is calculated using participants who undergo PCI as the denominator. | |
| Participants With Position-Related Serious Adverse Events or Prespecified Safety Events | From the start of the positioning intervention through 3 days after the procedure |
Show registry wordingNumber and proportion of participants experiencing a position-related serious adverse event or any prespecified safety event: hemodynamic instability, hypoxia, sustained arrhythmia, cerebral hypoperfusion, unplanned respiratory or circulatory support, mechanical collision, or emergency return to supine. | |