Clinical trial
Evaluation of the Reliability of a Wearable Device Combining Inertial Sensors and a Dynamometer for Analyzing Elbow Flexor Spasticity in Patients With Hemiplegia
NCT07950566 is registered in ClinicalTrials.gov with University Hospital, Montpellier as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started February 2027. Interventional study, 40 participants (estimated). Lead sponsor University Hospital, Montpellier; France. Primary measure: Inter-rater and intra-rater reproducibility of instrumental measurement for elbow flexor spasticity assessment.
How it compares
350 similar trials: same condition (Paresis) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- Evaluation of the Reliability of a Wearable Device Combining Inertial Sensors and a Dynamometer for Analyzing Elbow Flexor Spasticity in Patients With Hemiplegia
- Official title
- SENSAS - Evaluation of the Reliability of a Wearable Device Combining Inertial Sensors and a Dynamometer for Analyzing Elbow Flexor Spasticity in Patients With Hemiplegia
- Lead sponsor
- University Hospital, Montpellier
- Phase
- Not applicable
- Overall status
- Not yet recruiting
- Start date
- February 28, 2027
- Completion date
- February 28, 2029
- Enrollment
- 40 (estimated)
- Sites
- 1
Conditions
MeSH condition names; the registry's own terms follow.
Registry terms: hemiparesis, spasticity, upper extremity spasticity
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 18 Years
- Healthy volunteers
- No
- Study type
- Interventional
- Sites
- 1
- Countries
- France
- Lead sponsor
- University Hospital, Montpellier
Arms
As registered; 1 arm.
| Arm | Type | Interventions |
|---|---|---|
| Instrumented spasticity assessment | Experimental | K-Move/K-Push assessment system |
Show registry wordingAdults with unilateral spastic paresis undergoing standardized clinical and instrumental assessment of elbow flexor spasticity using inertial sensors (K-Move), a handheld dynamometer (K-Push), and the Modified Tardieu Scale. Measurements are repeated to evaluate inter-rater and intra-rater reproducibility. | ||
Primary endpoints
Registered primary outcome measures; 1 primary.
| Measure | Time frame |
|---|---|
| Inter-rater and intra-rater reproducibility of instrumental measurement for elbow flexor spasticity assessment | Day 1 and Day 2 |
Show registry wordingReproducibility of biomechanical parameters obtained from the instrumental measurement combining two inertial sensors (K-Move) and a portable dynamometer (K-Push) during passive elbow extension at three stretch velocities (slow, intermediate, and fast). Parameters include total elbow extension range of motion (in degrees), mean stretch velocity (in meters per second, m/s), angle of onset of spasticity (in degrees), referred to as the "catch", maximum resistance force measured by the dynamometer (in Newtons), mean resistance force measured by the dynamometer (in Newtons) over the entire movement, and extent of spastic resistance defined as the range of motion over which the resistance persists (in degrees). Inter-rater reproducibility will be assessed between two independent raters on Day 1, and intra-rater reproducibility will be assessed by repeated measurements performed by the same rater between Day 1 and Day 2. | |
Lead sponsor's other trials
University Hospital, Montpellier, most recent start first.
+1,258 more trials
Similar trials
Same condition (Paresis) and phase, most recent start first.
+345 more trials See the condition page