Clinical trial
Can Tailored Surgical Incisions Reduce Refractive Error and Dependence on Glasses After Cataract Surgery?
NCT07623317 is registered in ClinicalTrials.gov with Linkoeping University as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started September 2026. Interventional study, 100 participants (estimated). Lead sponsor Linkoeping University. Primary measure: Corneal astigmatismus. 3 linked papers (newest 2019).
How it compares
693 similar trials: same condition (Cataract) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- Can Tailored Surgical Incisions Reduce Refractive Error and Dependence on Glasses After Cataract Surgery?
- Official title
- A Prospective Randomized Controlled Study of How Construction and Placement of Surgical Corneal Incisions May Influence Refractive Errors and Spectacle Dependence After Cataract Surgery
- Lead sponsor
- Linkoeping University
- Phase
- Not applicable
- Overall status
- Not yet recruiting
- Start date
- September 15, 2026
- Completion date
- September 30, 2027
- Enrollment
- 100 (estimated)
- Sites
- Not reported
Conditions
MeSH condition names; the registry's own terms follow.
Registry terms: cataract (post-operative cataract surgery follow-up), refraction error
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 40 Years
- Maximum age
- 90 Years
- Healthy volunteers
- No
- Study type
- Interventional
- Lead sponsor
- Linkoeping University
Arms
As registered; 2 arms.
| Arm | Type | Interventions |
|---|---|---|
| Micro-Incision Cataract Surgery (MICS) with standardized surgical incisions | No intervention | |
Show registry wordingMain incision (1.8mm wide) is placed at the edge of the cornea, in an angle of 170 degrees (90 degrees is at 12 o´clock position, upwards). A minimal sideport is created at the edge of the cornea, approximately 90 degrees from the main incision. | ||
| MICS with surgical incisions tailored according to corneal astigmatismus | Experimental | Adapted clear corneal incisions |
Show registry wordingFor corneal astigmatismus with steep meridian axis in the interval 61-119 degrees, main incision (1.8mm wide) is placed in the steep axis. For astigmatismus larger than 1.5 dioptres, the main incision is enlarged to 2.75mm before placement of intra-ocular lens. For corneal astigmatismus with steep meridian axis in the intervals 0-60 degrees and 120-179 degrees, main incision (1.8mm wide) is placed in the steep axis. Before placement of intra-ocular lens, a corresponding incision is made at the edge of the cornea opposite to (180 degrees from) the primary main incision. For astigmatismus larger than 1.5 dioptres, the main incision is enlarged to 2.75mm before placement of intra-ocular lens, and the opposite incision is made to measure 2.75mm. | ||
Primary endpoints
Registered primary outcome measures; 1 primary.
| Measure | Time frame |
|---|---|
| Corneal astigmatismus | 3 and 12 weeks after cataract surgery |
Show registry wordingMagnitude and axis of corneal astigmatismus | |
Papers
PubMed papers this trial cites; 3 papers, results papers first, then newest first.
Lead sponsor's other trials
Linkoeping University, most recent start first.
+187 more trials See the organization page
Similar trials
Same condition (Cataract) and phase, most recent start first.
+688 more trials See the condition page