Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

Mechanical Power During Different Ventilation Modes in Laparoscopic Surgery

NCT07670494 is registered in ClinicalTrials.gov with Dr Abdurrahman Yurtaslan Ankara Oncology Training and Research Hospital as lead sponsor.

NCT NCT07670494 Recruiting Not applicable 80 participants (estimated) Started 2026 1 site

Follow this trial by email Email me the PDF

Get the NCT07670494 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Recruiting, started July 2026. Interventional study, 80 participants (estimated). Lead sponsor Dr Abdurrahman Yurtaslan Ankara Oncology Training and Research Hospital; Turkey (Türkiye). Primary measure: Device-Displayed Mechanical Power.

How it compares

70 similar trials: same condition (Ventilator-Induced Lung Injury) and phase

Enrollment

This trial
80
Middle half
20 to 105
Median
38
Trials with a value
70

Months from start to completion

This trial
6.4
Middle half
18 to 43.5
Median
27
Trials with a value
69

Sites

This trial
1
Middle half
1 to 1
Median
1
Trials with a value
62
Posted results or a linked paper 53% 37 of 70 similar trials; this trial: no

Registry record

As filed in ClinicalTrials.gov.

Title
Mechanical Power During Different Ventilation Modes in Laparoscopic Surgery
Official title
Comparison of Mechanical Power in Pressure-Regulated Volume Control and Volume-Controlled Ventilation Modes During Laparoscopic Cholecystectomy
Lead sponsor
Dr Abdurrahman Yurtaslan Ankara Oncology Training and Research Hospital
Phase
Not applicable
Overall status
Recruiting
Start date
July 1, 2026
Completion date
January 12, 2027
Enrollment
80 (estimated)
Sites
1

Conditions

MeSH condition names; the registry's own terms follow.

Ventilator-Induced Lung Injury

Registry terms: laparoscopic cholecystectomy, mechanical ventilation

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
18 Years
Healthy volunteers
Yes
Study type
Interventional
Sites
1
Countries
Turkey (Türkiye)
Lead sponsor
Dr Abdurrahman Yurtaslan Ankara Oncology Training and Research Hospital

Arms

As registered; 2 arms.

Registered arms
Arm Type Interventions
group A; VCV First, Then PRVC Experimental Pressure-Regulated Volume Control (PRVC), Volume-Controlled Ventilation (VCV)
Show registry wording

Following the stabilization of pneumoperitoneum, participants will be ventilated using the Volume-Controlled Ventilation (VCV) mode for 10 minutes. At the end of this period, respiratory data and mechanical power values will be recorded. Immediately after, the ventilator will be switched to the Pressure-Regulated Volume Control (PRVC) mode with equivalent settings. After another 10-minute stabilization period in PRVC mode, a second set of measurements will be recorded.

group B; PRVC First, Then VCV Experimental Pressure-Regulated Volume Control (PRVC), Volume-Controlled Ventilation (VCV)
Show registry wording

Following the stabilization of pneumoperitoneum, participants will be ventilated using the Pressure-Regulated Volume Control (PRVC) mode for 10 minutes. At the end of this period, respiratory data and mechanical power values will be recorded. Immediately after, the ventilator will be switched to the Volume-Controlled Ventilation (VCV) mode with equivalent settings. After another 10-minute stabilization period in VCV mode, a second set of measurements will be recorded.

Primary endpoints

Registered primary outcome measures; 1 primary.

Registered primary endpoints
Measure Time frame
Device-Displayed Mechanical Power At the end of a 10-minute stabilization period in each ventilation mode (VCV and PRVC).
Show registry wording

The mechanical power value (expressed in Joules per minute - J/min) is automatically calculated and displayed on the monitor of the Mindray A9 anesthesia machine. This value represents the total energy delivered by the ventilator to the patient's respiratory system per minute. The study aims to compare how this machine-calculated value differs between the Volume-Controlled Ventilation (VCV) and Pressure-Regulated Volume Control (PRVC) modes under identical clinical conditions.

Lead sponsor's other trials

Dr Abdurrahman Yurtaslan Ankara Oncology Training and Research Hospital, most recent start first.

Similar trials

Same condition (Ventilator-Induced Lung Injury) and phase, most recent start first.