Clinical trial
Bedside Ultrasound Measurement of Optic Nerve Sheath Diameter for Detecting Raised Intracranial Pressure
NCT07799714 is registered in ClinicalTrials.gov with Assiut University as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started October 2026. Observational study, 85 participants (estimated). Lead sponsor Assiut University. Primary measure: Area Under the Receiver Operating Characteristic Curve (AUC-ROC) for Detecting Raised Intracranial Pressure.
How it compares
31 similar trials: same condition (Brain Edema) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- Bedside Ultrasound Measurement of Optic Nerve Sheath Diameter for Detecting Raised Intracranial Pressure
- Official title
- Role of Bedside Ultrasound Measurement of Optic Nerve Sheath Diameter in the Early Detection of Raised Intracranial Pressure: A Comparative Study With CT Brain Findings
- Lead sponsor
- Assiut University
- Phase
- Observational
- Overall status
- Not yet recruiting
- Start date
- October 31, 2026
- Completion date
- November 30, 2027
- Enrollment
- 85 (estimated)
- Sites
- Not reported
Conditions
MeSH condition names; the registry's own terms follow.
Brain Edema, Brain Injuries, Traumatic, Intracranial Hypertension
Registry terms: increased intracranial pressure, traumatic brain injury
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 18 Years
- Study type
- Observational
- Lead sponsor
- Assiut University
Arms
As registered; 1 arm.
| Arm | Type | Interventions |
|---|---|---|
| Patients Suspected of Raised Intracranial Pressure | ||
Show registry wordingAdult patients aged 18 years or older with clinical suspicion of acutely raised intracranial pressure (e.g., altered consciousness, progressive headache, vomiting, papilledema, or focal neurological deficits) who are referred to undergo a non-contrast brain CT scan. ll enrolled participants undergo bedside transorbital high-resolution ultrasonography using a 7.5-15 MHz linear-array transducer to measure the optic nerve sheath diameter (ONSD) at 3 mm posterior to the globe in both eyes. Ultrasonographic findings are compared with non-contrast brain CT findings (the reference standard), which are independently evaluated by blinded neuroradiologists for signs of elevated intracranial pressure. | ||
Primary endpoints
Registered primary outcome measures; 1 primary.
| Measure | Time frame |
|---|---|
| Area Under the Receiver Operating Characteristic Curve (AUC-ROC) for Detecting Raised Intracranial Pressure | baseline |
Show registry wordingThe diagnostic performance of bedside transorbital optic nerve sheath diameter (ONSD) measurement in differentiating between patients with and without raised intracranial pressure will be evaluated using Receiver Operating Characteristic (ROC) curve analysis against the non-contrast brain CT reference standard. The Area Under the Curve (AUC) ranges from 0.5 (no discrimination) to 1.0 (perfect discrimination). | |
Lead sponsor's other trials
Assiut University, most recent start first.
+5,091 more trials See the organization page
Similar trials
Same condition (Brain Edema) and phase, most recent start first.
+26 more trials See the condition page