Heated, Humidified High-flow Nasal (HHHFN) Cannula vs Nasal Continuous Positive Airway Pressure in Respiratory Distress in Premature Neonates

NCT07891494 is registered in ClinicalTrials.gov with Pakistan Air Force (PAF) Hospital Islamabad as lead sponsor.

NCT NCT07891494 Completed Phase 4 100 participants (actual) Started 2024 1 site

Follow this trial by email Email me the PDF

Get the NCT07891494 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Completed, September 2025. Interventional study, Phase 4, 100 participants (actual). Lead sponsor Pakistan Air Force (PAF) Hospital Islamabad; Pakistan. Primary measure: Treatment Failure. 8 linked papers (newest 2024).

How it compares

10 similar trials: same condition (Respiratory Distress Syndrome, Newborn) and phase

Enrollment

This trial
100
Middle half
60 to 116
Median
98
Trials with a value
10

Months from start to completion

This trial
12.5
Middle half
27.2 to 45.9
Median
32
Trials with a value
10

Sites

This trial
1
Middle half
1 to 4
Median
1
Trials with a value
10
Posted results or a linked paper 70% 7 of 10 similar trials; this trial: yes

Registry record

As filed in ClinicalTrials.gov.

Title
Heated, Humidified High-flow Nasal (HHHFN) Cannula vs Nasal Continuous Positive Airway Pressure in Respiratory Distress in Premature Neonates
Official title
To Compare the Clinical Efficacy of Heated, Humidified High-Flow Nasal Cannula (HHHFN) and Nasal Continuous Positive Airway Pressure (nCPAP), as Primary Respiratory Support in Neonates With Respiratory Distress Who Are≥28 Weeks GA in Reducing the Need for IMV
Lead sponsor
Pakistan Air Force (PAF) Hospital Islamabad
Phase
Phase 4
Overall status
Completed
Start date
September 4, 2024
Completion date
September 20, 2025
Enrollment
100 (actual)
Sites
1

Conditions

MeSH condition names; the registry's own terms follow.

Respiratory Distress Syndrome, Newborn

Registry terms: neonatal respiratory distress syndrome

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
28 Weeks
Maximum age
37 Weeks
Healthy volunteers
No
Study type
Interventional
Sites
1
Countries
Pakistan
Lead sponsor
Pakistan Air Force (PAF) Hospital Islamabad

Arms

As registered; 2 arms.

Registered arms
Arm Type Interventions
Heated Humidified High-Flow Nasal Cannula therapy Group Active comparator Heated Humidified High-Flow Nasal Cannula therapy
N-CPAP Group Active comparator nCPAP

Primary endpoints

Registered primary outcome measures; 1 primary.

Registered primary endpoints
Measure Time frame
Treatment Failure 72 hours of starting treatment
Show registry wording

Efficacy will be assessed on basis of treatment failure. Treatment failure defined as requiring intubation or other non-invasive respiratory support within 72 h of starting intervention.

Mechanical ventilation will be considered when

1. Sustained increase in oxygen requirement: FiO2\>0.40 to maintain SpO2 of 90%-94% for more than 2 hour
2. Respiratory acidosis: potential of Hydrogen (pH)≤7.20 and PaCO2\>60 mm Hg
3. Frequent or severe apnea despite drug therapy or respiratory support: two or more apnea events requiring bag-mask ventilation within 24 h

Papers

PubMed papers this trial cites; 8 papers, results papers first, then newest first.

+3 more papers

Source: PubMed, NCBI/NLM (public domain).

Lead sponsor's other trials

Pakistan Air Force (PAF) Hospital Islamabad, most recent start first.

Similar trials