Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

Using an Artificial Intelligence Software Tool (iSeg) During Radiation Treatment Planning for Patients With Lung Tumors

NCT07898241 is registered in ClinicalTrials.gov with Northwestern University as lead sponsor.

NCT NCT07898241 Not yet recruiting Not applicable 34 participants (estimated) Started 2027 1 site

Follow this trial by email Email me the PDF

Get the NCT07898241 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Not yet recruiting, started February 2027. Interventional study, 34 participants (estimated). Lead sponsor Northwestern University; United States. Primary measures: Determination of lesion segmentation and accuracy; Overall contouring time.

How it compares

675 similar trials: same condition (Carcinoma, Non-Small-Cell Lung) and phase

Enrollment

This trial
34
Middle half
26 to 150
Median
60
Trials with a value
666

Months from start to completion

This trial
60.9
Middle half
24 to 68.2
Median
40.4
Trials with a value
650

Sites

This trial
1
Middle half
1 to 2
Median
1
Trials with a value
619
Posted results or a linked paper 41% 277 of 675 similar trials; this trial: no

Registry record

As filed in ClinicalTrials.gov.

Title
Using an Artificial Intelligence Software Tool (iSeg) During Radiation Treatment Planning for Patients With Lung Tumors
Official title
A Single-Arm Phase II Study of AI-Guided Individualized Segmentation (iSeg) in Patients With Lung Tumors
Lead sponsor
Northwestern University
Phase
Not applicable
Overall status
Not yet recruiting
Start date
February 13, 2027
Completion date
March 13, 2032
Enrollment
34 (estimated)
Sites
1

Conditions

MeSH condition names; the registry's own terms follow.

Carcinoma, Non-Small-Cell Lung, Lung Neoplasms

Registry terms: lung carcinoma, lung non-small cell carcinoma, metastatic malignant neoplasm in the lung

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
18 Years
Healthy volunteers
No
Study type
Interventional
Sites
1
Countries
United States
Lead sponsor
Northwestern University

Arms

As registered; 1 arm.

Registered arms
Arm Type Interventions
Treatment (iSeg, SBRT) Experimental Artificial Intelligence-based Intervention, Best Practice, Computed Tomography, Positron Emission Tomography, Radiology, Treatment Planning, Stereotactic Body Radiation Therapy, Survey Administration
Show registry wording

Patients undergo CT with standard of care radiation planning as well as physician and AI-directed segmentation of the tumor on study. One to two weeks later, patients undergo SBRT over 1-2 weeks in the absence of disease progression or unacceptable toxicity. Patients also undergo additional CT throughout the study and may undergo PET/CT as clinically indicated throughout the study.

Primary endpoints

Registered primary outcome measures; 2 primary.

Registered primary endpoints
Measure Time frame
Determination of lesion segmentation and accuracy Baseline
Show registry wording

The Dice Similarity Coefficient (DSC) and the 95th percentile Hausdorff Distance (HD95) will be calculated for each gross tumor volume (GTV) lesion by comparing physician de novo contours (P) with artificial intelligence (AI) contours (A). A linear mixed-effects model will be used to estimate the mean DSC(P, A\*) across all lesions while adjusting for patient-level clustering. The model will produce an estimated marginal mean DSC, its 95% confidence interval, and the one-sided p-value for the pre-specified hypothesis test of whether the mean DSC exceeds a clinically acceptable threshold. HD95(P, A) will be summarized descriptively using means, medians, and interquartile ranges. Sensitivity analyses will be performed if DSC values deviate substantially from normality; in such cases, per-patient mean DSC values will be computed and tested against the 0.72 threshold using a one-sample t-test or Wilcoxon signed-rank test.

Overall contouring time Baseline
Show registry wording

The primary workflow endpoint examines whether AI assistance reduces overall contouring time relative to de novo physician contouring. For each patient (and each lesion when distinct timing is recorded), the time required for physician de novo contouring (T\_P) and for physician review and modification of AI-generated contours (T\_\[A\^\* \]) will be compared. The primary analysis will use a paired t-test to estimate the mean absolute reduction in time and the corresponding percent reduction. If patients contribute multiple lesions with independently recorded times, a linear mixed-effects model with a patient-level random intercept will be used instead of a simple paired test. This model will estimate the mean difference in contouring time and the associated 95% confidence interval. Will test whether T\_P is greater than Atime, indicating a workflow efficiency gain attributable to AI guidance. Percent time reduction, defined as (T\_P- T\_(A\^\* )) / T\_P × 100%, will be summarized.

Lead sponsor's other trials

Northwestern University, most recent start first.

Similar trials

Same condition (Carcinoma, Non-Small-Cell Lung) and phase, most recent start first.