Clinical trial
Temporal Interference Stimulation Targeting Thalamus for Schizophrenia-Related Cognitive Dysfunction
NCT07927790 is registered in ClinicalTrials.gov with Central South University as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started November 2026. Interventional study, 80 participants (estimated). Lead sponsor Central South University; China. Primary measures: Changes in brain function; changes on the MATRICS Consensus Cognitive Battery (MCCB) scores.
How it compares
1,335 similar trials: same condition (Schizophrenia) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- Temporal Interference Stimulation Targeting Thalamus for Schizophrenia-Related Cognitive Dysfunction
- Official title
- Therapeutic Efficacy and Mechanism of Temporal Interference Stimulation on Thalamic-Mediated Cognitive Impairment in Schizophrenia
- Lead sponsor
- Central South University
- Phase
- Not applicable
- Overall status
- Not yet recruiting
- Start date
- November 30, 2026
- Completion date
- October 31, 2027
- Enrollment
- 80 (estimated)
- Sites
- 1
Conditions
MeSH condition names; the registry's own terms follow.
Cognitive Dysfunction, Schizophrenia
Registry terms: cognitive impairments, schizophrenia disorder
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 18 Years
- Maximum age
- 60 Years
- Healthy volunteers
- No
- Study type
- Interventional
- Sites
- 1
- Countries
- China
- Lead sponsor
- Central South University
Arms
As registered; 4 arms.
| Arm | Type | Interventions |
|---|---|---|
| Group A (A/S): Active stimulation first, followed by sham stimulation | Experimental | Sham TIS, temporal interference stimulation |
Show registry wordingGroup A receives active stimulation in the first session and sham stimulation in the second session.One day prior to each TIS session, participants complete two training runs of the Sternberg Item-Recognition Paradigm (SIRP) to eliminate confounding learning effects.Electrodes are placed according to the 10-10 EEG system and secured with conductive paste.Stimulation is individualized based on each participant's Individual Alpha Frequency (IAF). Resting-state EEG is recorded before stimulation to determine the IAF. A continuous high-frequency sinusoidal current pair with a base frequency of 2000 Hz and a beat frequency tuned to the IAF is delivered through each electrode to generate pulsed stimulation for individualized iTBS.Electric field modeling based on T1-weighted MRI images is used to optimize personalized electrode montages, ensuring an electric field strength ≥ 0.2 V/m within the left thalamus for each participant. | ||
| Group B (S/A): Sham stimulation first, followed by active stimulation | Sham comparator | Sham TIS, temporal interference stimulation |
Show registry wordingGroup B receives sham stimulation in the first session and active stimulation in the second session.One day prior to each TIS session, participants complete two training runs of the Sternberg Item-Recognition Paradigm (SIRP) to eliminate confounding learning effects. Electrodes are placed according to the 10-10 EEG system and secured with conductive paste.Stimulation is individualized based on each participant's Individual Alpha Frequency (IAF). Resting-state EEG is recorded before stimulation to determine the IAF. A continuous high-frequency sinusoidal current pair with a base frequency of 2000 Hz and a beat frequency tuned to the IAF is delivered through each electrode to generate pulsed stimulation for individualized iTBS.Electric field modeling based on T1-weighted MRI images is used to optimize personalized electrode montages, ensuring an electric field strength ≥ 0.2 V/m within the left thalamus for each participant. | ||
| sham group:Sham TIS | Sham comparator | Sham TIS |
Show registry wordingParticipants in the sham group receive sham TIS following the identical schedule: two sessions daily for 10 days, 20 sessions in total. The sham paradigm uses the same 2000 Hz current pair. Current is only delivered during the 10-second ramp-up and ramp-down phases at the start and end of each session, while no current is applied during the middle period. This setup mimics the scalp tingling sensation induced by current changes at the beginning and end of active stimulation. All other hardware, electrode placement and study procedures are identical to the active TIS group. | ||
| TIS group:TIS | Experimental | temporal interference stimulation |
Show registry wordingParticipants in the TIS group receive active TIS stimulation, with two intervention sessions per day for 10 consecutive days, totaling 20 sessions. Each session lasts 30 minutes. Electrodes are placed according to the 10-10 EEG system and secured with conductive paste. Stimulation is individualized based on each participant's Individual Alpha Frequency (IAF). Resting-state EEG is recorded before stimulation to determine the IAF. A continuous high-frequency sinusoidal current pair with a base frequency of 2000 Hz and a beat frequency tuned to the IAF is delivered through each electrode to generate pulsed stimulation for individualized iTBS. Electric field modeling based on T1-weighted MRI images is used to optimize personalized electrode montages, ensuring an electric field strength ≥ 0.2 V/m within the left thalamus for each participant. Each stimulation session lasts 30 minutes, with a 10-second ramp-up period at the onset and a 10-second ramp-down period at the end. | ||
Primary endpoints
Registered primary outcome measures; 2 primary.
| Measure | Time frame |
|---|---|
| Changes in brain function | baseline (T1 structural scan); pre-, during, and post-first stimulation (Day 1); pre-, during, and post-second stimulation (Day 9) |
Show registry wordingFunctional MRI (fMRI) is based on the blood oxygen level dependent (BOLD) contrast that can detect changes in blood oxygenation to analyze the change of brain function after intervention.This outcome is for sub-trial 1 (single-session crossover TIS). | |
| changes on the MATRICS Consensus Cognitive Battery (MCCB) scores | baseline,2 week visit, 4-week follow-up visit |
Show registry wordingThe MATRICS Consensus Cognitive Battery (MCCB) can be used for cognitive assessment of schizophrenia, bipolar disorder, and other neuropsychiatric diseases. The MCCB covers nine cognitive domains, including attention, information processing speed, verbal learning and memory, visual learning and memory, spatial working memory, reasoning, problem solving, social cognition, executive function, and fine motor skills. The working memory domain does not include verbal working memory because the Chinese language would not make feasible the inclusion of the LNS test.This outcome is for sub-trial 2 (2-week repeated TIS). | |
Lead sponsor's other trials
Central South University, most recent start first.
+131 more trials See the organization page
Similar trials
Same condition (Schizophrenia) and phase, most recent start first.
+1,330 more trials See the condition page