Clinical trial
Effect of Different Adhesive Removal Techniques After Orthodontic Bracket Debonding on Postoperative Hypersensitivity: A Randomized Clinical Trial
NCT07935902 is registered in ClinicalTrials.gov with Asmaa Badr Abdelfatah as lead sponsor.
Follow this trial by email Email me the PDF
Summary
Not yet recruiting, started November 2026. Interventional study, 15 participants (estimated). Lead sponsor Asmaa Badr Abdelfatah; Egypt. Primary measure: Postoperative Hypersensitivity.
How it compares
200 similar trials: same condition (Dentin Sensitivity) and phase
Registry record
As filed in ClinicalTrials.gov.
- Title
- Effect of Different Adhesive Removal Techniques After Orthodontic Bracket Debonding on Postoperative Hypersensitivity: A Randomized Clinical Trial
- Official title
- Not reported
- Lead sponsor
- Asmaa Badr Abdelfatah
- Phase
- Not applicable
- Overall status
- Not yet recruiting
- Start date
- November 30, 2026
- Completion date
- October 31, 2027
- Enrollment
- 15 (estimated)
- Sites
- 1
Conditions
MeSH condition names; the registry's own terms follow.
Registry terms: orthodontic adhesive removal, postoperative hypersensitivity
Who could take part, where it ran, who ran it
As filed in ClinicalTrials.gov.
- Sex
- All
- Minimum age
- 15 Years
- Maximum age
- 45 Years
- Healthy volunteers
- Yes
- Study type
- Interventional
- Sites
- 1
- Countries
- Egypt
- Lead sponsor
- Asmaa Badr Abdelfatah
Arms
As registered; 4 arms.
| Arm | Type | Interventions |
|---|---|---|
| Active Comparator: Low-Speed Tungsten Carbide Bur | Active comparator | Low-Speed Tungsten Carbide Bur |
Show registry wordingResidual composite adhesive remnants on eligible teeth are cleaned using a 12-fluted low-speed tungsten carbide bur operated at 15,000-20,000 rpm under continuous water cooling. | ||
| Fiberglass Bur | Experimental | Fiberglass Bur |
Show registry wordingResidual composite adhesive remnants on eligible teeth are cleaned using a fiberglass bur operated at 15,000-20,000 rpm under continuous water cooling | ||
| White Stone Bur | Experimental | White Stone Bur |
Show registry wordingResidual composite adhesive remnants on eligible teeth are cleaned using a fine-grit white stone bur (aluminum oxide) operated at 10,000-15,000 rpm under continuous water cooling. | ||
| Rubber-Impregnated Polishing Point | Experimental | Rubber-Impregnated Polishing Point |
Show registry wordingResidual composite adhesive remnants on eligible teeth are cleaned using a rubber-impregnated polishing point operated at 10,000-15,000 rpm under continuous water cooling | ||
Primary endpoints
Registered primary outcome measures; 1 primary.
| Measure | Time frame |
|---|---|
| Postoperative Hypersensitivity | Baseline (immediately post-debonding, before clean-up), 24 hours, and 7 days post-adhesive removal. |
Show registry wordingPatient-reported pain and hypersensitivity evaluated using a Visual Analogue Scale (VAS) score ranging from 0 (No pain) to 10 (Unbearable severe pain) in response to a 2-second dental syringe air-blast stimulus test. | |
Similar trials
Same condition (Dentin Sensitivity) and phase, most recent start first.
+195 more trials See the condition page