Skip to content
Pharma Observatory a Scientist.com platform

Clinical trial

Procedural Endpoint in Left Bundle Branch Area Pacing: Conduction System Capture Versus LV Septal Capture

NCT07804394 is registered in ClinicalTrials.gov with Yonsei University as lead sponsor.

NCT NCT07804394 Not yet recruiting Not applicable 300 participants (estimated) Started 2026

Follow this trial by email Email me the PDF

Get the NCT07804394 report as a PDF

The PDF carries up to 50 rows of each section, where the page shows the first few, with the sources listed. Enter a work email and confirm it from the message we send, and the report follows by email.

Summary

Not yet recruiting, started October 2026. Interventional study, 300 participants (estimated). Lead sponsor Yonsei University. Primary measure: Change from baseline in left ventricular ejection fraction (LVEF) at 12 months. 2 linked papers (newest 2022).

How it compares

51 similar trials: same condition (Bundle-Branch Block) and phase

Enrollment

This trial
300
Middle half
29 to 177
Median
60
Trials with a value
51

Months from start to completion

This trial
38
Middle half
27.8 to 55
Median
45
Trials with a value
50

Sites

This trial
Not reported
Middle half
1 to 3
Median
1
Trials with a value
49
Posted results or a linked paper 57% 29 of 51 similar trials; this trial: yes

Registry record

As filed in ClinicalTrials.gov.

Title
Procedural Endpoint in Left Bundle Branch Area Pacing: Conduction System Capture Versus LV Septal Capture
Official title
COMparisons of Different Procedural endPoints in pAtients Who undeRgo Left Bundle Branch arEa Pacing: Direct Capture of Left Ventricular Conduction SYstem Versus Left veNtricular Septal Capture (COMPARE-SYNC): A Multicenter, Prospective, Randomized Controlled Study
Lead sponsor
Yonsei University
Phase
Not applicable
Overall status
Not yet recruiting
Start date
October 1, 2026
Completion date
November 30, 2029
Enrollment
300 (estimated)
Sites
Not reported

Conditions

MeSH condition names; the registry's own terms follow.

Arrhythmias, Cardiac, Atrioventricular Block, Bradycardia, Bundle-Branch Block, Cardiomyopathies, Sick Sinus Syndrome, Ventricular Dysfunction

Registry terms: artificial, cardiac pacing, heart conduction system, left

Who could take part, where it ran, who ran it

As filed in ClinicalTrials.gov.

Sex
All
Minimum age
19 Years
Healthy volunteers
No
Study type
Interventional
Lead sponsor
Yonsei University

Arms

As registered; 2 arms.

Registered arms
Arm Type Interventions
LBBP mandatory group Experimental LBBAP with mandatory left ventricular conduction system capture (LBBP or LFP)
Show registry wording

Participants undergo LBBAP in which direct capture of the left ventricular conduction system is mandatory. The procedure continues until left bundle branch pacing (LBBP) or left fascicular pacing (LFP) is confirmed by at least one predefined conduction system capture criterion. If conduction system capture cannot be obtained at the initial site, the lead is repositioned and the attempt repeated; more than three attempts are generally not recommended, with the final decision left to the operator. Failure to achieve conduction system capture is recorded as a protocol deviation.

LVSP enough group Active comparator LBBAP with left ventricular septal capture as the accepted procedural endpoint (LVSP)
Show registry wording

Participants undergo LBBAP in which left ventricular septal capture alone is accepted as the procedural endpoint. Once deep septal placement within the left ventricular subendocardial region is confirmed together with a terminal R-wave in lead V1 (LVSP), the operator may complete the procedure at his or her discretion irrespective of whether direct conduction system capture is achieved. Voluntary additional lead advancement in an attempt to obtain conduction system capture is permitted but not required.

Primary endpoints

Registered primary outcome measures; 1 primary.

Registered primary endpoints
Measure Time frame
Change from baseline in left ventricular ejection fraction (LVEF) at 12 months Baseline and 12 months (±3 months) after implantation
Show registry wording

Absolute change in LVEF (percentage points) from baseline to 12 months, compared between the LBBP mandatory group and the LVSP enough group. LVEF is measured by the Simpson biplane method on transthoracic echocardiography and is determined by a central echocardiography core laboratory whose readers are blinded to treatment allocation, participating site, and acquisition time point. Baseline and 12-month studies are read as pairs by the same reader with the time point order randomly presented, in order to minimise measurement error in the change score. Only core laboratory values are used in the analysis; values reported by the enrolling site are collected for reference only. The primary analysis is an analysis of covariance with 12-month LVEF as the dependent variable and treatment group, baseline LVEF, and the stratification factor as covariates.

Papers

PubMed papers this trial cites; 2 papers, results papers first, then newest first.

Source: PubMed, NCBI/NLM (public domain).

Lead sponsor's other trials

Yonsei University, most recent start first.

Similar trials

Same condition (Bundle-Branch Block) and phase, most recent start first.